19.42.030 Form and intensity standards for mixed-use and industrial zones.
The following table describes the form and intensity standards in mixed-use and industrial zones. Form and intensity standards for the aeronautical zone are located in AMC 19.42.170 and for the public use zone in AMC 19.42.180.
Measure |
CBD |
C |
MMU |
CM |
CM2 |
LM |
LM1 |
MS |
I |
HM |
Conditions/Reference |
LOT SIZE AND DEVELOPMENT INTENSITY |
|||||||||||
Density minimum (dwelling units/gross acre) |
15 |
15 |
15(X) |
(X) East of Q Avenue only |
|||||||
Maximum building size without a conditional use permit (gross floor area) |
200,000 |
300,000 |
200,000 |
||||||||
Landscaped area, minimum percentage |
10% |
10% |
10% |
15% |
15% |
10% |
10% |
10% |
10% |
See AMC 19.65.030 for landscaped area provisions |
|
HEIGHT (feet)—PRINCIPAL STRUCTURES |
|||||||||||
Height, base maximum |
50 |
40 |
35—45 |
35 |
50 |
35—50 |
50 |
50 |
50 |
50 |
See AMC 19.42.120 for building height exceptions and modifications |
Height, maximum with bonus |
65(X) |
50 |
50—65(X) |
50 |
50(Y) |
See AMC 19.42.050 through 19.42.070 (X) AMC 19.42.120(C)(7) (Y) AMC 19.42.120(C)(1) |
|||||
SETBACKS (feet) |
|||||||||||
NOTE: The setbacks below apply to principal structures, unless otherwise noted, except where accessory structure setbacks are modified by AMC 19.47.020(B). |
|||||||||||
Street setback, minimum |
0 |
0 |
0 |
10 |
10 |
10 |
10 |
10 |
15 |
15 |
See AMC 19.42.130(B) for street setback measurements See AMC 19.42.150 for possible setback modifications Also see AMC Chapter 19.61, Block Frontage Standards |
NOTE: Most nonresidential and multifamily development must conform to block frontage standards of AMC Chapter 19.61, which affect the street setbacks. |
|||||||||||
Interior side setback, minimum |
0(X) (Y) (Z) |
0(X) (Y) |
0(X) (Y) |
0(X) (Y) |
0(Y) |
10(X) (Y) |
10(Y) |
10(Y) |
10(Y) |
10(Y) |
(X) AMC 19.62.030(C) regarding multifamily uses along internal property lines (Y) AMC 19.42.150(C) regarding setbacks to adjoining residential zones (Z) AMC 19.42.150(D) when site abuts OT-zoned property |
Rear setback, minimum |
0 |
0 |
0 |
0 |
0 |
10 |
10 |
10 |
10 |
10 |
|
(where they differ from setbacks above) |
|||||||||||
Interior side setback, minimum |
0 |
0 |
0 |
0 |
0 |
3—5 (see AMC 19.47.020(B) for details and exceptions) |
|||||
Rear setback, minimum |
0 |
0 |
0 |
0 |
0 |
0—10 (see AMC 19.47.020(B) for details and exceptions) |
(Ord. 3040 § 2 (Att. A), 2019)